+91 70057 36620ilustraca.edu@gmail.com
STRUCTDESK · WEB APP

PEB Frame Designer

Design pre-engineered steel buildings in your browser: main frames, purlins, girts, gable ends and wind bracing to IS 800:2026, IS 875 and IS 1893, with every calculation shown in equation form.

IS 800:2026 / 2007IS 801IS 875IS 18933D analysis

Nothing to install · Runs in your web browser · Save and reopen your projects

Please log in or create an account first, then choose your plan.

What it does

Main frames to IS 800

Single gable, multi-gable and mono-slope frames. Tapered or uniform plated members, or rolled sections, sized by the optimiser for the lightest frame within your target ratio.

Every IS 800 check

Section class (Table 2) and slender webs, shear and shear buckling, LTB with outer and inner flange restraint, axial buckling (Annex D), combined N + M at every point for every ULS combination.

Loads to IS 875 and IS 1893

Dead, services, imposed (auto to IS 875-2), dust, wind to IS 875-3 (WL1–WL6 with ±Cpi) and seismic to IS 1893, with IS 800 Table 4 combinations generated.

Diagrams and envelopes

Moment, shear, axial, deflection, reactions and a utilisation contour for any load case, combination or envelope (max in red, min in blue, governing case named).

Purlins, girts, gable ends, bracing

Cold-formed purlins and girts to IS 801 with sag rods, gable ends with openings, and roof, side-wall and end-wall X bracing with braced bays to Cl. 3.10.3.

Optional 3D building analysis

Analyse the whole building in 3D; main frames and bracing are re-sized until every member passes with the 3D forces.

Report in equation form

Load derivation, combinations, diagrams, reactions for foundations and the full IS 800 calculation of every member, with symbols defined. Print or save as PDF.

DXF, STAAD, ETABS, MIDAS

DXF drawings with section callouts; 2D frame and 3D building models for STAAD.Pro (.std), ETABS (.e2k) and MIDAS Gen NX (.mgt); reactions as CSV.

Full feature list

Main frame analysis and design (2D)
  • The optimiser sizes every column and rafter segment, tapered or uniform plated sections or rolled sections, for the lightest weight that keeps every check at or below your target ratio.
  • IS 800 checks at every element end for every ULS combination: section classification (Table 2), effective section for slender webs, shear and shear buckling (8.4), high-shear moment reduction, lateral-torsional buckling (8.2.2, Annex E), axial buckling with effective length from Annex D, and combined N + M (9.3.1, 9.3.2.2).
  • Outer flange restrained by purlins and girts, inner flange by flange braces at the spacing you give.
  • c1 for LTB as a value (default 1.0) or automatic from the moment diagram over each unbraced length.
  • Notional horizontal forces (0.5 %) in gravity combinations; serviceability limits on rafter deflection and eave sway.
  • Click any member for its full IS 800 calculation.
Inputs, step by step
1. Project informationProject, building, job number, revision, engineer, checker
2. Building geometrySingle gable, multi-gable or mono-slope; spans, eave height, roof slope; equal or unequal bays; building length; girt and purlin spacing; base pinned or fixed; rafter and column flange-brace spacing
3. LoadsSheeting, services, purlin/girt self-weight, imposed load (auto or user), dust; wind to IS 875-3 (city, Vb, terrain, k1–k4, Kd, Kc, Cpi, Cpe auto or user); seismic to IS 1893 (zone, importance, R, soil, damping); optional seismic along the building
4. Frame members & segmentsColumn and rafter segments, tapered or uniform, plated or rolled; depth ranges; ridge and knee haunches; presets
5. Sections, plates & gradesPlate thicknesses and widths, plate grade, rolled-section sets (IS 808, Jindal and others), filters
6. Purlins & girtsSection set or user section, cold-formed grade, simple or continuous lapped, sag rods (auto or 0–4), deflection limit, local wind factor
7. Design settings2D frames, or 2D design + 3D building analysis; target ratio; slender webs; IS 800:2026 or :2007; deflection limits; c1; effective-length overrides
8. Gable ends & wind bracingPost-and-beam or rigid end frames, end-wall columns, door openings with jambs and headers, braced bays, rods or angles, X-panel tiers, frictional drag
Loads and combinations
  • Load cases: DL, SL (services), LL, DU (dust), WL1–WL6 (wind across and along, ±Cpi), EQ, and EQY when enabled.
  • ULS combinations per IS 800 Table 4; service combinations for reactions; deflection checks with imposed load alone (Table 6).
  • Foundation reactions for factored (IS 456) and service (IS 875-5) combinations, with CSV export.
Results, views and diagrams
Frame ElevationSections to scale, applied loads, moment, shear, axial, deflected shape, base reactions, capacity vs moment envelope, utilisation contour; purlins, girts and flange braces overlaid
3D ViewWhole building, rotate/zoom/pan, layers, colour by member type, section or utilisation, extruded or line view, deformed shape, applied loads
3D ResultsAny frame line, side wall or roof plan: P, V2, M3, M2, torsion, deflection, reactions
Roof Plan / End Wall / Side WallPurlins, bracing, struts, braced bays; gable framing by utilisation, openings, girts; wall bracing tiers
Section LibraryRolled and cold-formed section databases
ReportFull design report, ready to print or save as PDF

Every force, deflection and reaction can be shown for a single load case, a combination or an envelope.

Purlins, girts, gable ends and bracing
  • Purlins and girts to IS 801, simple or continuous, sag rods auto (lightest kg/m²) or chosen; their weight goes onto the frames.
  • Gable ends as post-and-beam or rigid frame with wind columns; end-wall columns rolled or built-up; jambs, headers and girts around openings.
  • Roof X-bracing truss, side-wall and end-wall X bracing with tier options, strut purlins and eave strut; braced bays to IS 800 Cl. 3.10.3; frictional drag to IS 875-3 Cl. 7.4.1.
Optional 3D building analysis
  • Frames, end walls, purlins, girts, eave struts and X bracing analysed together as one 3D structure.
  • Main frames and bracing are re-sized automatically until every member passes with the 3D forces.
  • Frame members re-checked to IS 800 with the 3D forces, including minor-axis moment.
Outputs and exports
Design reportSummary, inputs, load derivation (wind, seismic), combinations, diagrams, reactions, serviceability, full IS 800 member calculations, purlins and girts, gable ends and bracing, quantities
DXF drawingsFrame elevation with cross-sections and plate callouts, end-wall and side-wall elevations
2D frame modelsSTAAD.Pro (.std), MIDAS Gen NX (.mgt) and ETABS (.e2k) with tapered members, loads and combinations
3D building modelsWhole building for STAAD.Pro, MIDAS Gen NX and ETABS with releases, tension-only bracing, supports, load cases and combinations
3D loading reportHow every load in the 3D model is applied, with case totals
Foundation reactionsCSV of service and factored base reactions
Project file.sdpeb file to save and reopen a project
Easy to use
  • Familiar desktop-style layout: menus and toolbar, Model Explorer, view windows and an output panel.
  • Right-click menus on members, views, load cases and the 3D model.
  • F5 runs the design, Ctrl+S saves, Ctrl+O opens. Light theme, with a dark theme under Options.
Scope
  • Designed for regular single-storey portal-frame buildings: single gable, multi-gable and mono-slope. Not covered: mezzanines, cranes, canopies, parapets, fascia, roof monitors, lean-to frames, skewed plans, sloping ground.
  • Connections, base plates, anchor bolts, stiffeners and foundations are not designed; base reactions are given.
  • A design aid: every result must be reviewed by a qualified structural engineer.

How it works

1Create your account

Confirm your email and the 7-day free trial starts.

2Enter the building

Geometry, loads, members and design settings, step by step.

3Run and export

Press Run design, review the checks, print the report and export the model.

Plans

FREE TRIAL7 days
  • Full design, gable ends, purlins and girts
  • Report with TRIAL watermark
  • No STAAD / MIDAS / ETABS export
Create free account
PAY PER HOUR₹299 / hour
  • Full access, no watermark
  • All exports: STAAD, MIDAS, ETABS, DXF

Hours run from purchase, not from use. Your time starts the moment payment succeeds and runs continuously, even if you close the tool. Example: buy 2 hours at 3:00 pm and access ends at 5:00 pm.

Buy hours
MONTHLY₹2,999
  • 30 days full access
  • Clean reports, no watermark
  • All exports: STAAD, MIDAS, ETABS (2D and 3D), DXF
Subscribe · 1 month
YEARLY · BEST VALUE₹24,999
  • 365 days full access
  • Clean reports, no watermark
  • All exports: STAAD, MIDAS, ETABS (2D and 3D), DXF
Subscribe · 1 year

Payments by UPI, cards or net banking through Razorpay. Access starts as soon as payment succeeds and runs on the clock (hourly passes included), whether or not the tool is open; buying again adds the time to your current access. Plans do not renew automatically.

Log in or create an account

We will email you a link to confirm your address; your 7-day free trial starts when you confirm. By creating an account you agree to the Terms and Privacy policy.

Design aid only; results must be reviewed by a qualified structural engineer. Support: ilustraca.tech@gmail.com · +91 70057 36620

Talk to us

Questions about a course, a StructDesk licence, or inviting Er. Sandip Deb for a lecture or workshop? Get in touch.

Phone / WhatsApp+91 70057 36620
Emaililustraca.edu@gmail.com
Message on WhatsApp
error: Content is protected !!
Scroll to Top