IS 800 has been revised for the fourth time. The new IS 800:2026 (General Construction in Steel, October 2026) is not a light update: working stress design is gone, the whole code is renumbered, section classification limits are tighter, and the earthquake clause has been rewritten. This guide compares the two editions clause by clause, with small interactive tools so you can see what changes for your own designs.

24clauses, flat numbering (was 17 sections)
WSDworking stress design removed
a0new buckling curve, α = 0.13
NewClause 23: sustainable steel construction

1. Find your clause in the new code

Every clause has moved. The old sections are now numbered clauses, the old Section 11 (working stress design) has been deleted, and in places the numbering inside a section has shifted. Pick a clause from the list (or type its number or name) to find its equivalent in the other edition. If a clause number does not exist in the code you are looking at, the finder will tell you.

Interactive · Clause finder
Loading the clause lists…

Clause lists and names are read from the published IS 800:2007 and IS 800:2026. Matches are made by clause number and name; where the numbering shifted, the finder says so. Always confirm with the code.

2. The big-picture changes

AreaIS 800:2007IS 800:2026
Design methodLimit state design plus working stress design (Section 11)Working stress design removed. Only limit state design and plastic theory remain.
Code structure17 Sections (1–17)Flat clause numbering, 1–24. New: 23 Sustainable Steel Construction and 10.3 Fire Loads.
Foreign codes consideredAS 4100, BS 5950, CAN/CSA S16.1, ENV 1993EN 1993-1-1 (Eurocode 3); many new provisions follow Eurocode.
Seismic linkIS 1893 onlyIS 1893 (Part 1) plus IS 18168:2023 (earthquake-resistant design and detailing of steel structures)
TermsLive load, earthquake loadImposed load, earthquake effects

3. Section classification: tighter limits

Table 2 has been reorganised and most limits are now tighter, so a section that was plastic or compact under the 2007 code may drop a class. Enter your steel’s yield stress to see the actual b/t limits, and switch between the editions.

Interactive · Table 2 explorer
ε = √(250/fy) = 1.000

Values are limits on the width-to-thickness ratio for Class 1 (plastic) / Class 2 (compact) / Class 3 (semi-compact). In Compare mode, red values are tighter in 2026 (the section is more likely to drop a class) and green values are more relaxed.

  • Elliptical hollow sections are new (equivalent diameter De). The definitions of r1 and r2 have changed.
  • Class 4 (slender) sections can now be designed: via IS 801, or by deducting the plate width beyond the semi-compact limit (new Fig. 2C), using Zeff in bending. In 2007, slender sections were outside the scope of the code.

4. Do you need second-order analysis?

Second-order effects now have their own clause, 11.7. The λcr limits that applied only to plastic analysis in 2007 now apply to elastic analysis too, and a first-order elastic analysis no longer needs amplification automatically.

Interactive · Clause 11.7 check

Clad: ≥ 10 first order OK; 4.6–10 amplify; < 4.6 second-order analysis. Unclad: ≥ 20 first order OK; 5.75–20 amplify; < 5.75 second-order analysis. The old δp = 0.9λcr/(λcr − 1) is replaced by amplification per 11.7.3 and 16.3.2.2. Earthquake effects must now be obtained by elastic analysis only.

5. Lateral torsional buckling: αLT is no longer fixed

In 2007, the imperfection factor αLT was simply 0.21 for rolled and 0.49 for welded sections. In 2026 it comes from Table 13 and depends on the section’s shape. Pick a section to compare.

Interactive · Table 13
IS 800:20070.21
IS 800:2026–

Also new: χLT includes a moment-gradient factor fm (Table 14): χLT = fm / [φLT + √(φLT² − fm·λLT²)] ≤ 1.0. An equivalent compression flange method (with slenderness correction kc) is added for LTB checks, and plate girders with corrugated webs are covered in the new Annex G.

6. Column base bearing: check this one carefully

The bearing strength under a column base changes from a flat 0.6 fck to 0.3 fck·√(A1/A2) ≤ 0.9 fck. At A1 = A2 the new value is half the old one. Try your numbers.

Interactive · Column base bearing
IS 800:2007 · 0.6 fck–
IS 800:2026 · 0.3 fck√(A1/A2) ≤ 0.9 fck–

Also new: a minimum of 4 anchor bolts, and a minimum of 6 for slab bases transferring earthquake forces.

7. Everything else, topic by topic

Pick a topic to see what changed.

Materials (Table 1)

  • IS 2062 grades now follow IS 2062 (Part 1):2025: E165 removed, E275 added, grades carry A/BR/B0/C sub-grades, and the old E450 (Fe 590) E grade is dropped (E450 is listed as A/BR only).
  • New steels in Table 1: IS 15103 (fire-resistant), IS 11587 (weather-resistant), IS 15962 (improved seismic resistance: E250S, E300S, E350S, E450S).
  • Submerged-arc welding wire and flux now refer to IS 15977 (in place of IS 7280 and IS 3613).

Loads and load combinations (Table 4)

  • Fire load (FL) is a new load type: forces from restrained expansion during a fire. New combination DL + IL + FL with 1.0 DL, 1.0 IL for storage areas (0.5 IL otherwise) and 1.0 FL.
  • The old combined row “DL+LL+CL+WL/EL” is split into separate wind and earthquake rows. EL row: 1.2 DL + 1.2 IL + 1.2 EL. EL serviceability row: DL 1.0, IL 0.8, EL 1.0.
  • Accidental-load combination: new footnote. The 0.35 factor is not to be used when the imposed load is not permanent.
  • Partial safety factors for materials (Table 5) are unchanged.

Temperature effects and expansion joints

  • The expansion-joint rules (50 / 90 / 230 m etc.) now apply only to low-rise buildings up to 3 storeys. For high-rise buildings, refer to specialist literature.
  • The exemption from temperature stress analysis now applies only to steel frames with elastic steel cladding.
  • The expansion-joint gap must now also prevent pounding of adjacent units during earthquake shaking.

Compression members

  • Buckling curve a0 (α = 0.13) added (Table 7, Fig. 8).
  • Table 10, buckling class: new column for fy > 420 MPa (e.g. rolled I, h/b > 1.2, tf ≤ 40 mm: a0 about z-z, a about y-y). Cold-formed hollow sections: b → c. Rolled angles: c → b (a for fy > 420). Welded angles stay c. Cruciform column added; “built-up member” row removed.
  • Single angles loaded through one leg, new method: fcd,e = Kf·χaa·fy/γm0, with Kf = k1 + k2λaa + k3λφ and χaa from class b about the axis parallel to the gusset. This replaces the old λe = √(k1 + k2λvv² + k3λφ²). For how this method compares with tests, read our article on single angle struts by Dr. N. Subramanian and co-authors.
  • Base stiffness: new pile-cap guidance. The pedestal is taken as fixed at the top of the pile cap when single piles are tied with ground beams both ways; a single pile cap with stiff orthogonal beams is fixed at its top.

Serviceability (Table 6)

  • Relative displacement between crane rails: 10 mm → 25 mm (the crane supplier may be consulted for higher values).
  • Crane load is now included for rafter deflection. Other limits are essentially unchanged.

Earthquake design (old Section 12 → new Clause 18)

Item20072026
Frame types allowedOCBF and OMF not allowed in Zones IV/V, or Zone III with I > 1Zone II: ordinary frames allowed. Zone III and above: only special frames (18.1.2)
R valuesTable 23: OCBF 4, SCBF 4.5, EBF 5, OMF 4, SMF 5OCBF, SCBF, SEBF, SMF: R from IS 1893 (Part 1). OEBF 4.5, OMF 4.0, NDF 1.5 (new)
HSFG / fitted boltsAll seismic framesCritical zones only (plastic hinge zone = 2 × member depth, plus bracing connections)
SMF steel gradeE250BE250BR / E250B0
OMFShow 0.02 rad joint rotationBasis-of-design approach; beams/columns plastic or compact; strong column–weak beam; bi-directional yielding considered
SCBF bracing connections12.8.3 (1.1 fyAg, 1.2 Mp)Clause dropped; SCBF splices no longer need 50% flexural strength
EBFSpecialist literatureSplit into OEBF and SEBF, both by specialist literature
Industrial buildings (new 18.13)–Single-storey regular frames, H/span < 1.0: NDF with R = 1.5, exempt from ductility detailing; connections for full member capacity, +50% in Zone V

Fire, durability and fatigue

  • Fire: the old Tl = 905 − 690·rf is replaced. Reduce fy, E and G (new) with temperature, re-run the member capacity checks, and find the temperature at which capacity equals the fire-case design action (including the new FL combination and restraint forces). For TMCP steels, use the manufacturer’s data.
  • Durability and fatigue: essentially the same content, renumbered.

New Clause 23: Sustainable steel construction

  • Duties for the employer, main contractor, engineers and steelwork contractor, including a carbon reduction plan.
  • Material-efficient design: utilisation close to 1.0, higher grades where serviceability doesn’t govern, no over-specified loads.
  • Design for adaptability and deconstruction; sustainable fabrication (waste, welding, coatings).
  • Records: EPDs, embodied carbon, as-erected digital records. New definitions (embodied carbon, design for deconstruction, etc.).

Annexes and fabrication

  • Old Annex H (plastic properties of ISMB and other beams) removed. Tender recommendations move from Annex G to Annex H; Annex G is now corrugated webs.
  • Fabrication: hole clearances now refer to Table 20 (same values); minor additions such as grinding out gouges deeper than 5 mm.
  • Hole clearances (Table 20, old 19) and slip factors (Table 21, old 20) are unchanged.

⚠ Points to watch in the 2026 text

  • Column base bearing: at A1 = A2 the new formula gives 0.3 fck: half the old 0.6 fck and below IS 456’s 0.45 fck. Check against any amendment before use.
  • Contradictory zone rules: 18.1.2 allows only special frames in Zone III and above, but 18.7.1.1 bars OCBF only in Zone IV and above (or Zone III with I > 1). Clauses 18.7.1 and 18.7.3.3 also read as garbled.

Method: both standards were compared clause by clause. The 2007 PDF is a scanned copy, so its tables were checked against page images; small wording changes in long running text may not be captured. Design values above are taken directly from the tables. Always refer to the published standard for design.

– views
Was this article helpful?
Subscribe to the Ilustraca blog
Get new articles on structural analysis and design in your inbox. No spam, unsubscribe any time.
Share this article
Picture of Er. Sandip Deb

Er. Sandip Deb

Founder of Ilustraca Academy and a practising structural engineer in Kolkata. B.Tech (Civil), AMIE, CEng(I), Empanelled Structural Engineer with NKDA & KMC. He teaches RCC and steel design the way design offices work, with every software result checked by hand against the IS codes.